Vector and Cozmo Robot Troubleshooting

No Response When Placed on Charger

Troubleshooting Steps:

  1. Verify charger outputs 5V with multimeter
  2. Clean charging contacts on robot
  3. Test with known good battery
  4. If problem persists, replace screen/speaker assembly

Cozmo Display Stays Off After Lifting Arms While On Charger

Cause: Disconnected wire on lift gear microchip
Solution: Disassemble and check lift gear wiring connections

Lift Doesn't Work Correctly

Cause: Broken lift gear teeth
Solutions:

  1. Remove arms and manually rotate lift gear
  2. Feel for rough spots indicating broken teeth
  3. Rotate past broken section and reassemble
  4. For complete repair: disassemble, replace broken gears, or remove debris

Robot powers off after a short time

Complete Power Loss

Causes: Likely dead battery
Solution: Replace battery (503040 lipo)


Cozmo Password Connection Issues

Troubleshooting Steps:

  1. Enter password exactly as displayed (preserve dashes and capitalization)
  2. Power cycle Cozmo and retry connection
  3. Some units require multiple connection attempts
  4. If persistent issues, the Wi-Fi adapter may be faulty
Back to blog

Leave a comment

Please note, comments need to be approved before they are published.